400 Series Curtainwall

400 Series Curtainwall Cutaway

Designed for low- and mid-rise applications, the durable framework of the 400 Series Curtainwall provides exceptional structural performance reducing the need for steel reinforcing. This system has a sightline of 2 1/2” and the strength of variable-depth backmembers from 4” to 8”. An exterior screw-applied pressure bar secures the glass.

Snap-on covers, available in a wide range of colors, allow for different finishes on interior and exterior exposed surfaces. Silicone-glazed verticals are available for a seamless appearance.

400 Series Curtainwall, 14000 Series Storefront; Sandstone Paint; East Tennessee State University Library; Architect: Ken Ross Architects / David Leonard Associates; Glazing Contractor: Keller Glass

Crown Cork & Seal Curtainwall

400 Series Curtainwall, 1900 Series Ribbon Window; Champagne Gold Paint; Crown Cork & Seal; Architect: Ballinger Architects; Glazing Contractor: Hutt’s Glass; Photography: Esto Photographics

400 Series Curtainwall Product Specifications
Application: Face Width: Back-member Depths: Face Depths Overall Depths: Glass
Thickness:
Air Infiltration: Dynamic Water: Structural Overload: CRF*: U Value1
Alum PP:
U Value2
Fiberglass PP:
Sound Transmission:
Mid-Rise Curtainwall & High Performance Storefronts 1/2 5/8“, 4”, 5”, 51/2“, 6”, 7”, & 8” 5/8“, 3/4“, 1”, 11/2“, 2”, 21/2 51/2” to 113/4 1” 0.03 CFM/Ft.2
@6.24 PSF
15 PSF 90 PSF 68 (Frame)
59 (Glass)
0.39 0.34 32 STC
26 OITC
400 Series Curtainwall Product Specifications
Application: Mid-Rise Curtainwall & High Performance Storefronts
Face Width: 2 1/2
Back-member Depths: 5/8“, 4”, 5”, 5 1/2“, 6”, 7”, & 8”
Face Depths 5/8“, 3/4“, 1”, 1 1/2“, 2”, 2 1/2
Overall Depths: 5 1/2” to 11 3/4
Glass Thickness: 1”
Air Infiltration: 0.03 CFM/Ft.2
@6.24 PSF
Dynamic Water: 15 PSF
Structural Overload: 90 PSF
CRF*: 68 (Frame), 59 (Glass)
U Value1: 0.39
U Value2: 0.34
Sound Transmission: 32 STC, 26 OITC
* See Tubelite’s Test Reports for mock up sizes and test conditions.
1 Glass Type = 1/4″ SB70XL #2 / 1/2″ Argon / 1/4″ Clear with warm edge spacer. COG U-factor = 0.24. All results represent NFRC 100 standard opening sizes of 78.74″ x 78.74″ for frames and 75.59″ x 82.28″ for doors.
2 Results Obtained from NFRC 100-200-500 Simulation using a 5 ½” back member.
400 Series Curtainwall Technical Data
Technical Data Index: Click to go to the index
Material Safety Data Sheets: ZIP File
CAD File (DWG): ZIP File
BIM Models: Zip File
Details: PDF File
Fiberglass PP PDF File
Installation Instructions: Concealed & Exposed Fasteners
400CW-SSG
Glazing Chart
Specs: Text File
Windload Charts: PDF File
400 Series Curtainwall Test Reports – Aluminum Pressure Plate
Air-Water Structural 2009 Structural
2012 Structural
Torque Specs
AAMA 1503 2012 Captured
2013 SSG
Archive Structural [1998]
Structural [2006]
CRF Simulation E5TB223
E55TB223
E7TB02
E8TB02
NFRC CMAST E4TB223
E5TB223
E55TB223
E7TB02
E8TB02
SSG Simulation
cma-approved-logo-small
400 Series Curtainwall Test Reports – Fiberglass Pressure Plate
STC PDF File
AAMA 501 PDF File
AAMA 1503 PDF File
NFRC CMAST NFRC 102-2010Uc, SHGC, VT – CMA 4” to 8”
NFRC Simulation Uc, SHGC, VT & CR – 4”
Uc, SHGC, VT & CR – 4 1/2
Uc, SHGC, VT & CR – 5”
Uc, SHGC, VT & CR – 5 1/2
Uc, SHGC, VT & CR – 6”
Uc, SHGC, VT & CR – 7”
Uc, SHGC, VT & CR – 8”
400 Series Curtainwall Submittal Booklets
4 Inch PDF File
5 Inch PDF File
5.5 Inch PDF File
6 Inch PDF File
7 Inch PDF File
8 Inch PDF File
Curtainwall Brochure
Tubelite Curtainwall Brochure PDF File
Fiberglass Pressure Plate Flyer
Fiberglass_PP_Sheet
PDF File


400 Screw Spline Curtainwall

Tubelite_400SS

Tubelite 400SS Screw Spline Curtainwall is an exterior-glazed, thermally improved pressure wall system. This gasket glazed, weeped system will accept infill material up to 1” thick, positioned at the frame exterior for a minimum of metal exposure. A screw applied pressure plate secures the infill material and snap fits with a cover plate to conceal fasteners and allow for two color installations. Open-back jambs and 2-piece intermediate verticals allow screw spline joints. This reduces the need for shear blocks, fabrication time and installation labor costs.

400SS Curtainwall has a 2-1⁄2” sight line and is available in variable depth from 5-7/8” to 13-1⁄4” through face-cover/backmember combinations. It is recommended for use on low-to-medium rise structures.

400SS Series Curtainwall Product Specifications
Application: Face Width: Back-member Depths: Face Depths Overall Depths: Glass
Thickness:
Air Infiltration: Dynamic Water: Structural Overload: CRF*: U Value1: Sound Transmission:
Mid-Rise Curtainwall & High Performance Storefronts 1/2 3/4“, & 5 1/4 5/8“, 3/4“, 1”, 1 1/2“, 2”, 2 1/2 6” &
7 1/2
1” 0.01 CFM/Ft.2
@6.24 PSF
15 PSF 75 PSF 68 (Frame)
56 (Glass)
0.37 NA
400SS Series Curtainwall Product Specifications
Application: Mid-Rise Curtainwall & High Performance Storefronts
Face Width: 2 1/2
Back-member Depths: 3 3/4“, & 5 1/4
Face Depths 5/8“, 3/4“, 1”, 1 1/2“, 2”, 2 1/2
Overall Depths: 6” &
7 1/2“”
Glass Thickness: 1”
Air Infiltration: 0.01 CFM/Ft.2 @6.24 PSF
Dynamic Water: 15 PSF
Structural Overload: 75 PSF
CRF*: 68 (Frame), 56 (Glass)
U Value1: 0.37
Sound Transmission: NA
* See Tubelite’s Test Reports for mock up sizes and test conditions.
1 Glass Type = 1/4″ SB70XL #2 / 1/2″ Air / 1/4″ Clear. COG U-factor = 0.29. Results obtained from AAMA 507 reports unless otherwise noted. All results represent NFRC 100 standard opening sizes of 78.74″ x 78.74″ for frames and 75.59″ x 82.28″ for doors.
400SS Series Curtainwall Technical Data
Technical Data Index: Click to go to the index
Material Safety Data Sheets: ZIP File
CAD File (DWG): 400SS ZIP File
BIM Models: CAD Details SEEK
Details: PDF File
Installation Instructions: PDF File
Glazing Chart
Test Reports: PDF File
AAMA 507
Specs: Text File
Windload Charts: PDF File
Curtainwall Brochure
Tubelite Curtainwall Brochure PDF File
Fiberglass Pressure Plate Flyer
Fiberglass_PP_Sheet
PDF File


400 IG Curtainwall

Tubelite_400IG

Tubelite 400 Series I.G. (Inset Glaze) Curtainwall Framing for low and medium rise applications has been redesigned for installation labor savings and design flexibility. Offset glass pockets and removable glass stops on the new 400 Series allow glazing or re-glazing from both the exterior and interior of the building. Broken lites can be replaced without removing the vertical pressure plates or snap covers. The new roll-over horizontal member permits erection of all the verticals first, to reduce installation time and cost. Open back head and jamb members provide economical alternatives to the previous hollow tube perimeters
400IG Series Curtainwall Product Specifications
Application: Face Width: Back-member Depths: Face Depths Overall Depths: Glass
Thickness:
Air Infiltration: Dynamic Water: Structural Overload: CRF*: U Value1
:
Sound Transmission:
Mid-Rise Curtainwall 1/2 5/8“, & 5 1/4 5/8“, 3/4“, 1”, 1 1/2“, 2”, 2 1/2 3/4” & 7 3/8 1” 0.01 CFM/Ft.2
@6.24 PSF
12 PSF +/- 45 PSF 63 (Frame)
56 (Glass)
0.54 NA
400 Series Curtainwall Product Specifications
Application: Mid-Rise Curtainwall
Face Width: 2 1/2
Back-member Depths: 5/8” & 5 1/4
Face Depths 5/8“, 3/4“, 1”, 1 1/2“, 2”, 2 1/2
Overall Depths: 5 3/4” to 7 3/8
Glass Thickness: 1”
Air Infiltration: 0.01 CFM/Ft.2
@6.24 PSF
Dynamic Water: 12 PSF
Structural Overload: +/- 45 PSF
CRF*: 63 (Frame), 56 (Glass)
U Value1: 0.54
Sound Transmission: NA
* See Tubelite’s Test Reports for mock up sizes and test conditions.
1 Glass Type = 1/4″ SB70XL #2 / 1/2″ Argon / 1/4″ Clear with warm edge spacer. COG U-factor = 0.24. All results represent NFRC 100 standard opening sizes of 78.74″ x 78.74″ for frames and 75.59″ x 82.28″ for doors.
2 Results Obtained from NFRC 100-200-500 Simulation using a 5 ½” back member.
400IG Series Curtainwall Technical Data
Technical Data Index: Click to go to the index
Material Safety Data Sheets: ZIP File
CAD File (DWG): 400 IG 3-5/8 ZIP File
400 IG 5-1/4ZIP File
BIM Models: CAD Details
SEEK
Installation Instructions: PDF File
Glazing Chart
Test Reports: PDF File
Specs: Word File
Windload Charts: PDF File
Curtainwall Brochure
Tubelite Curtainwall Brochure PDF File
Fiberglass Pressure Plate Flyer
Fiberglass_PP_Sheet
PDF File