ForceFront Storm™ E44000 Storefront

ForceFront Storm: Entrances – Monumental Stile 2″ | Medium Stile 1 3/4″ | Storefront- E44000 | E/T34000 | Curtainwall – 2 1/2″

header_storefront

Introducing ForceFront Storm™ E44000 Storefront

Tubelite E44000 Series Framing is a 2 1/2” x 5″ flush-glazed storefront system for use on first floor, single-span applications in Impact building code areas. This impact resistant screw-spline framing is designed to be glazed with 9/16” laminated glass positioned in the center of the frame. E44000 meets the requirements of HVHZ Wind Zone 4 – large missile impact [ASTM E1886-05/1996-09 TAS 201]

Forcefront Medium Stile Entrance Doors complement the E44000 storefront system providing a complete impact-resistant system that’s easy to fabricate and install. These doors meet the requirements of Wind Zone 3 – large missile impact [ASTM E1886- 05/1996-09] and passed the forced entry test [AAMA 1304-02]

E44000 is available with Tubelite’s high recycled aluminum content, and both the storefront and doors with the environmentally friendly anodizing and painting of Linetec.

Testing

E44000 ForceFront Impact-Resistant Framing

  • Static [ASTM E 331] and Dynamic [AAMA 501.1] Water @ 10.5 psf.
  • Air Infiltration [ASTM E 283] 0.03cfm/ft2 @ +6.24 psf
  • Design Pressure
        • At +50/-50 psf with standard int. vertical
        • At +70/-70 psf with heavy interior vertical and steel reinforcing at the door jamb only
  • Large Missile Impact Test – [ASTM E1886-05/1996-09 TAS 201]

ForceFront Medium Stile Entrance Doors

  • Designed for compliance with HVHZ Wind Zone 2, – Large Missile Impact, [ASTM E1886-05/E1996-09 TAS 201]
  • 50psf +/- cyclic loading for 3’0” x 7’0“ single doors thru 6’0”x7’0” pairs
  • Forced Entry Test [AAMA 1304-02]
  • Large Missile Impact Test – [ASTM E1886-05/1996-09]

GET THE POINT!™

E44000 Storefront can help with the following LEED points:

  • MR 4.1 & 4.2 Recycled Content
  • MR 5.1 & 5.2 Regional Materials
  • EQ 8.1 & 8.2 Daylight & Views
ForceFront Storm Storefront E44000 Product Specifications
System
(2 1/2″x5″)
Glass Size (max) Frame Height
(max)
Structural Missile Type Interlayer
Makeups Tested*
Texas Department of Insurance (TDI) Florida Product Approval (FPA) Florida Building Code HVHZ
E44000 Non Thermal
(dry glazed)
46 3/4” x 120″ 123 3/4 + 70 / – 70 psf Large (D) 1/4” HS – .075 Solutia
Vanceva – 1/4” HS
CWFS-42
Evaluation
Drawing
FL16507 Storefront
FL16044 Doors
No

ForceFront Storm Storefront E44000 Product Specifications

System (2 1/2″x5″) Glass Size (max) Frame Height (max) Structural Missile Type Interlayer Makeups Tested* Texas Department of Insurance (TDI) Florida Product Approval (FPA) Florida Building Code HVHZ
Single Span Captured
(dry glazed)
46 3/4” x 120” 123 3/4 +70 / -70 psf Large (D) 1/4” HS – .075 Solutia
Vanceva – 1/4” HS
CWFS-42
Evaluation
Drawing
FL16507 Storefront
FL16044 Doors
No
E44000 Series Technical Data
Technical Data Index Click here to go to the index
Material Safety Data Sheets ZIP File
CAD File (DWG): ZIP File
Details: PDF File
Installation Instructions: PDF File
Test Reports: C4532.01-450-18-R0
C9499.01-450-18-R0
C2166 01-450-44-R0
Specs: PDF
Word File
Windload Charts: PDF File
ForceFront Storm E44000 Flyer