Tubelite® ForceFront Storm Monumental Wide Stile entrance doors are designed for compliance with ASTM, GSA ISC and DoD requirements for charge weight and standoff. They have also passed the forced entry test [AAMA 1304-02]. These 6” Wide Stile doors are glazed with 1-1/16” thick laminated insulated glass and are wet glazed on the interior side. Transom glass in all door frames are wet glazed. Door frames are non-thermal, and are available with options for heavy-wall extrusions and steel reinforcing where required. Thresholds are equipped with bulb weatherseal gaskets and are ADA accessible. Hinging hardware options include heavy duty morised butts and continuous gear hinges. All types of locking, push/pull hardware, and door closers are allowed.

A complete evaluation performed by a Professional Engineer is required for each project.

ForceFront Storm Monumental Wide Stile Doors Testing

  1. Arena and shock tube testing performed
  2. ASTM F 1642-04, UFC 4-010-01, GSA-TS01-2003 protocols
  3. Glass qualified: SG
  4. Testing results: ·
    • Exceeds 6 psi – 42 psi-msec
    • Charge weight of 550 lbs. at 153 ft. stand-off
  5. ForceFront Monumental Doors have been analyzed in accordance with UFC 4-101-01 Oct. 2013 and ASTM F2248 Storm resistance criteria using calculation and SBEDS software, and has been found to comply with 148 ft standoff Charge Weight I, and 82 ft Charge Weight II in illustrated configurations. Each project must be analyzed separately for compliance based on project-specific charges, standoffs, product sizes, and substrates, with shop drawings prepared for each project.
GET THE POINT!™

ForceFront E/T34000 Storefront can help with the following LEED points:

  • EQ 8.1 & 8.2 Daylight & Views
Product Matrix: ForceFront Storm – Entrances
Application Stile Width: Frame Depth
or Max Size:
Water
Infiltration [psf]:
Test
Pressure:
Outside HVHZ
-Approved:
Impact
Approval:
Inside HVHZ
– Approved:
Glass Types
Tested:

Single up to 3’0” x 7’0”

Pairs up to 6’0” x 7’0”

6″ Single Leaf:
48″ x 96″
Pair: 96″ x 96″
+/-100 Yes Yes
FL14563.2
Yes
FL14563.1
GL-1) 1 1/16
insulated laminated
with 0.090”
DuPont SentryGlas

Product Matrix: ForceFront Storm™ – Monumental Entrances

Application Stile Width: Frame Depth or Max Size: Water Infiltration [psf]: Test Pressure Outside HVHZ – Approved Impact Approval InsideHVHZ – Approved Glass Types Tested
Single up to 3’0” x 7’0”

Pairs up to 6’0” x 7’0”

6″ Single Leaf: 48″ x 96″ Pair: 96″ x 96″ +/-100 Yes Yes FL14563.2 YesFL14563.1 GL-1) 1 1/16” insulated laminated with 0.090” DuPont SentryGlas
Force Front Storm – Monumental Entrances Technical Data
Technical Data Index: Click here to go to the index
Material Safety Data Sheets: ZIP File
BIM Models: MonDr Single wMuntin Zip File
MonDr Pair wMuntin Zip File
MonDr Pair Zip File
Monumental Wide Stile Doors – HVHZ
Details: Hurricane Series Monumental Doors
HVHZ Monumental Doors
Installation Instructions: Fabrication and Installation PDF
Test Reports: Tubelite HVHZ Evaluation Report
Wolters Affirmation Evaluation Report
Tremco Gasket Evaluation Report
Dupont SentryGlas Evaluation Report
HTL Evaluation Report
Monumental Wide Stile Doors
Details: Non-HVHZ Monumental Doors
Installation Instructions: Fabrication and Installation PDF
Test Reports: Wolters Non-HVHZ Evaluation Report
Tubelite Non-HVHZ Evaluation Report

ForceFront Storm Curtainwall Flyer
FFS-Monumental-Stile-2016 PDF File