ForceFront® Blast

ForceFront Blast

ForceFront Blast LogoBlast Hazard Mitigation Systems- Framing and Entrances – Tubelite’s Force Front Blast standard and monumental entry door systems, storefront and curtainwall are now available for DoD, GSA, VA and other low- and mid-rise buildings requiring protection from blast hazard threats.

  • ForceFront Blast

Blast Hazard Mitigation Systems- Framing and Entrances – pressure bar curtainwall framing and wide stile monumental doors are designed for compliance with ASTM, GSA ISC and DoD requirements. Fully tested and easy to fabricate and install, ForceFront Blast framing systems are designed and engineered for single span storefronts, and punched opening applications. The curtainwall and storefront framing provides improved thermal performance and both the doors and curtainwall are dry-glazed with insulated glass for energy efficiency.

Check out the following ForceFront Blast products we have to offer:

ForceFront Blast Storefront

E34000 ForceFront Blast

Product Info »

  • 2-1/2″ Sight line
  • 5″ Depth
  • Center plane glass
  • Non thermal
  • Infill: 1-5/16″
  • Blast resistant

34000 ForceFront Blast Storefront Framing

  • ForceFront Blast

T34000 ForceFront Blast

Product Info »

  • 2-1/2″ Sight line
  • 5″ Depth
  • Center plane glass
  • Thermal
  • Infill: 1-5/16″
  • Blast resistant

34000 ForceFront Blast Storefront Framing

  • ForceFront Blast

ForceFront Blast Entrances

ForceFront Blast Standard Medium

Product Info »

  • 4″ stiles and top rail
  • 10″ bottom rail
  • 1 3/4″ depth
  • Blast hazard mitigation for DOD UFC, GSA, VA
  • Tie-rod frame construction – lifetime warranty
  • Infill: 9/16″ to 1-3/16″ lami IGU

  • Project - Wendy’s - Cemetery Road, Hilliard, OH - Storefront, Curtainwall, Doors - 2015
  • ForceFront Blast
  • Project - The Factory - Nashville, TN - Storefront - 2006

ForceFront Blast Standard Wide

Product Info »

  • 5″ stiles and top rail
  • 10″ bottom rail
  • 1 3/4″ depth
  • Blast hazard mitigation for DOD UFC, GSA, VA
  • Tie-rod frame construction – lifetime warranty
  • Infill: 9/16″ to 1-3/16″ lami IGU

  • Project - Wendy’s - Cemetery Road, Hilliard, OH - Storefront, Curtainwall, Doors - 2015
  • ForceFront Blast
  • Project - The Factory - Nashville, TN - Storefront - 2006

ForceFront Blast Monumental Medium

Product Info »

  • 4 1/2″ stiles and top rail
  • 10″ bottom rail
  • 2″ depth
  • Blast hazard mitigation for DOD UFC, GSA, VA
  • Tie-rod frame construction – lifetime warranty
  • Infill: 9/16″ to 1-3/16″ lami IGU

  • Project - Wendy’s - Cemetery Road, Hilliard, OH - Storefront, Curtainwall, Doors - 2015
  • ForceFront Blast
  • Project - The Factory - Nashville, TN - Storefront - 2006

ForceFront Blast Monumental Wide

Product Info »

  • 6″ stiles and top rail
  • 10″ bottom rail
  • 2″ depth
  • Blast hazard mitigation for DOD UFC, GSA, VA
  • Tie-rod frame construction – lifetime warranty
  • Infill: 9/16″ to 1-3/16″ lami IGU

  • Project - Wendy’s - Cemetery Road, Hilliard, OH - Storefront, Curtainwall, Doors - 2015
  • ForceFront Blast
  • Project - The Factory - Nashville, TN - Storefront - 2006

ForceFront Blast Curtainwall

ForceFront Blast Curtainwall

Product Info »

  • 2-1/2″ sightline
  • Thermally Broken
  • Shear block frame construction
  • GSA, DoD & VA requirements

  • Project - Wendy’s - Cemetery Road, Hilliard, OH - Storefront, Curtainwall, Doors - 2015
  • Project - TC Parking Garage - Traverse City, MI - Storefront, Entrance - 2006
  • Project - The Factory - Nashville, TN - Storefront - 2006